mosquitto/test/broker/06-bridge-b2br-disconnect-qos2.py

135 lines
4.4 KiB
Python
Raw Normal View History

2019-03-28 21:32:12 +00:00
#!/usr/bin/env python3
2014-05-07 22:27:00 +00:00
# Does a bridge resend a QoS=1 message correctly after a disconnect?
2018-11-27 11:26:21 +00:00
from mosq_test_helper import *
2014-05-07 22:27:00 +00:00
2019-10-09 12:27:23 +00:00
def write_config(filename, port1, port2, protocol_version):
with open(filename, 'w') as f:
f.write("port %d\n" % (port2))
f.write("\n")
f.write("connection bridge_sample\n")
f.write("address 127.0.0.1:%d\n" % (port1))
f.write("topic bridge/# both 2\n")
f.write("notifications false\n")
f.write("restart_timeout 5\n")
2019-10-09 12:27:23 +00:00
f.write("bridge_protocol_version %s\n" % (protocol_version))
2019-10-09 12:27:23 +00:00
def do_test(proto_ver):
if proto_ver == 4:
bridge_protocol = "mqttv311"
proto_ver_connect = 128+4
else:
bridge_protocol = "mqttv50"
proto_ver_connect = 5
2019-10-10 13:51:32 +00:00
(port1, port2) = mosq_test.get_port(2)
conf_file = os.path.basename(__file__).replace('.py', '.conf')
2019-10-09 12:27:23 +00:00
write_config(conf_file, port1, port2, bridge_protocol)
rc = 1
keepalive = 60
client_id = socket.gethostname()+".bridge_sample"
connect_packet = mosq_test.gen_connect(client_id, keepalive=keepalive, clean_session=False, proto_ver=proto_ver_connect)
connack_packet = mosq_test.gen_connack(rc=0, proto_ver=proto_ver)
2019-10-10 13:51:32 +00:00
if proto_ver == 5:
opts = mqtt5_opts.MQTT_SUB_OPT_NO_LOCAL | mqtt5_opts.MQTT_SUB_OPT_RETAIN_AS_PUBLISHED
else:
opts = 0
2019-10-09 12:27:23 +00:00
mid = 1
2019-10-10 13:51:32 +00:00
subscribe_packet = mosq_test.gen_subscribe(mid, "bridge/#", 2 | opts, proto_ver=proto_ver)
2019-10-09 12:27:23 +00:00
suback_packet = mosq_test.gen_suback(mid, 2, proto_ver=proto_ver)
mid = 2
2019-10-10 13:51:32 +00:00
subscribe2_packet = mosq_test.gen_subscribe(mid, "bridge/#", 2 | opts, proto_ver=proto_ver)
2019-10-09 12:27:23 +00:00
suback2_packet = mosq_test.gen_suback(mid, 2, proto_ver=proto_ver)
mid = 3
2019-10-10 13:51:32 +00:00
subscribe3_packet = mosq_test.gen_subscribe(mid, "bridge/#", 2 | opts, proto_ver=proto_ver)
2019-10-09 12:27:23 +00:00
suback3_packet = mosq_test.gen_suback(mid, 2, proto_ver=proto_ver)
mid = 5
publish_packet = mosq_test.gen_publish("bridge/disconnect/test", qos=2, mid=mid, payload="disconnect-message", proto_ver=proto_ver)
publish_dup_packet = mosq_test.gen_publish("bridge/disconnect/test", qos=2, mid=mid, payload="disconnect-message", dup=True, proto_ver=proto_ver)
pubrec_packet = mosq_test.gen_pubrec(mid, proto_ver=proto_ver)
pubrel_packet = mosq_test.gen_pubrel(mid, proto_ver=proto_ver)
pubcomp_packet = mosq_test.gen_pubcomp(mid, proto_ver=proto_ver)
ssock = socket.socket(socket.AF_INET, socket.SOCK_STREAM)
ssock.setsockopt(socket.SOL_SOCKET, socket.SO_REUSEADDR, 1)
ssock.settimeout(40)
ssock.bind(('', port1))
ssock.listen(5)
2014-05-07 22:27:00 +00:00
2019-10-09 12:27:23 +00:00
try:
broker = mosq_test.start_broker(filename=os.path.basename(__file__), port=port2, use_conf=True)
(bridge, address) = ssock.accept()
bridge.settimeout(20)
2014-05-07 22:27:00 +00:00
2020-08-12 10:06:09 +00:00
mosq_test.expect_packet(bridge, "connect", connect_packet)
bridge.send(connack_packet)
2014-05-07 22:27:00 +00:00
2020-08-12 10:06:09 +00:00
mosq_test.expect_packet(bridge, "subscribe", subscribe_packet)
bridge.send(suback_packet)
2014-05-07 22:27:00 +00:00
2020-08-12 10:06:09 +00:00
bridge.send(publish_packet)
bridge.close()
2014-05-07 22:27:00 +00:00
2020-08-12 10:06:09 +00:00
(bridge, address) = ssock.accept()
bridge.settimeout(20)
2014-05-07 22:27:00 +00:00
2020-08-12 10:06:09 +00:00
mosq_test.expect_packet(bridge, "connect", connect_packet)
bridge.send(connack_packet)
2014-05-07 22:27:00 +00:00
2020-08-12 10:06:09 +00:00
mosq_test.expect_packet(bridge, "2nd subscribe", subscribe2_packet)
bridge.send(suback2_packet)
bridge.send(publish_dup_packet)
2014-05-07 22:27:00 +00:00
2020-08-12 10:06:09 +00:00
mosq_test.expect_packet(bridge, "pubrec", pubrec_packet)
bridge.send(pubrel_packet)
bridge.close()
2014-05-07 22:27:00 +00:00
2020-08-12 10:06:09 +00:00
(bridge, address) = ssock.accept()
bridge.settimeout(20)
2014-05-07 22:27:00 +00:00
2020-08-12 10:06:09 +00:00
mosq_test.expect_packet(bridge, "connect", connect_packet)
bridge.send(connack_packet)
2014-05-07 22:27:00 +00:00
2020-08-12 10:06:09 +00:00
mosq_test.expect_packet(bridge, "3rd subscribe", subscribe3_packet)
bridge.send(suback3_packet)
2014-05-07 22:27:00 +00:00
2020-08-12 10:06:09 +00:00
bridge.send(publish_dup_packet)
2014-05-07 22:27:00 +00:00
2020-08-12 10:06:09 +00:00
mosq_test.expect_packet(bridge, "2nd pubrec", pubrec_packet)
bridge.send(pubrel_packet)
2014-05-07 22:27:00 +00:00
2020-08-12 10:06:09 +00:00
mosq_test.expect_packet(bridge, "pubcomp", pubcomp_packet)
rc = 0
2014-05-07 22:27:00 +00:00
2019-10-09 12:27:23 +00:00
bridge.close()
2020-08-12 10:06:09 +00:00
except mosq_test.TestError:
pass
2019-10-09 12:27:23 +00:00
finally:
os.remove(conf_file)
try:
bridge.close()
except NameError:
pass
2014-05-07 22:27:00 +00:00
2019-10-09 12:27:23 +00:00
broker.terminate()
broker.wait()
(stdo, stde) = broker.communicate()
ssock.close()
if rc:
print(stde.decode('utf-8'))
exit(rc)
2014-05-07 22:27:00 +00:00
2019-10-09 12:27:23 +00:00
do_test(proto_ver=4)
do_test(proto_ver=5)
2014-05-07 22:27:00 +00:00
2019-10-09 12:27:23 +00:00
exit(0)
2014-05-07 22:27:00 +00:00